    Book Descriptions:

    clv u40 manual

    Keep this and all related instruction manuals in a safe, accessible location. If you have any questions or comments about any information in this manual, please contact Olympus. Terms used in this manual OES video converter, OES video system: Signup up today for the latest offers and discounts. Email. Menu manuals of all equipment which will be used during the procedure and use the equipment as instructed. Terms used in this manual OES video converter, OES video system: Signup up today for the latest offers and discounts. Email. Menu Equipment that has been disassembled, repaired, altered, changed, or modified by persons other than Olympus' own authorized service personnel is excluded from Olympus' limited warranty and is not warranted by Olympus in any manner. By actuating the Mode Selector, the light source can be set for any scope. From the EVIS 100, 130, 140, and 200 Series videoscopes to the OES fiberscopes and all rigid endoscopes.Manual override offers variable adjustment by the endoscopist. Manual override gives the endoscopist complete control of this function. Condition: Very good, fully functional. I have 1x Olympus CV-160, 3x Olympus CLV 145, 2x Olympus CV-145, 1x K-4 OLYMPUS suction pump, 7x Olympus CV-140 and 3x Olympus CLV U40. By actuating the Mode Selector, the light source can be set for almost any scope - from the EVIS 100, 130, 140, and 200 Series videoscopes can also be used with the Q180 series, but it voids the NBI functioning to the OES fiberscopes and all rigid endoscopes. Only in combination with 200 series scopes. Optimum Light Density Adjustment for Video Taping Automatically selects the ideal sensitivity required. Manual override offers variable adjustment by the endoscopist. Manual override gives the endoscopist complete control of this function. Built-In Emergency Lamp The CLV-U40 system includes a built-in 150W Halogen emergency lamp which is automatically actuated in the event of Xenon lamp failure.

    • clv u40 manual, olympus clv-u40 manual, olympus clv-u40 service manual, clv u40 manual, clv u40 manual pdf, clv u40 manual download, clv u40 manuals, clv u40 manual instructions.

    Sign in Forgot Password. My Bench Close Sign In Not A Member. Sign Up Join MedWrench OK name type Receive Summary Emails. FORUMS View All (1) Ask a New Question 1 Reply -Engr Zohaib 2 months ago 2 months ago Lamp Light not working Hello! Sir,It seems like a point is missing(ground). Please share service manual, Thanks for your response. Regard. Zohaib By continuing to browse the site you are agreeing to our use of cookies. Please review our Privacy Policy for more details. All Rights Reserved. It is able to fragment the hardest stones and the largest stone burdens efficiently in far shorter times than single action devices. Evis CLV-U40 Light Source For Sale Auction. Search and Browse hundreds of Medical Equipment Auctions on DOTmed.com Olympus CLV-U40 Xenon Light Source; Olympus CLV-U40 Xenon Light Source. Out of stock. MAKE AN OFFER. Part Number: CLV-U40. Compare; Contact On This Product. Request a quote online or call 1-800-438-7662.Olympus offers replacement instruction manuals for most models as free downloads. Softbound printed copies are also available for some models. To acquire these manuals or a variety of other Olympus reference documentation, follow the easy fr.dotmed.com Olympus CLV-160 Evis Exera Light Source Olympus Updated: 2007-09-10 With its improved condenser lens design and powerful 300W xenon lamp, the EVIS EXERATM 160 Series' dedicated light source, the CLV-160, is able to generate 30% more light intensity than its predecessor, the CLV-U40. Olympus Evis Exera lll CV-190 Video Processor. Request a Quote. Product details. Olympus Evis Exera lll CLV-190 Imaging System Xenon Light Source. Request a Quote. Product details. OLYMPUS EXERA II CV-180 HDTV Video Processor. Request a Quote. Product details. OLYMPUS EXERA II CLV-180 300W XENON LIGHT SOURCE WITH NARROW BAND IMAGING (NBI) Request a Quote. Product manuals of all equipment which will be used during the procedure and use the equipment as instructed.

    Olympus CLV-U40 Features: Automatic sensitivity includes override capability for variable adjustment Trans-illumination confirms target area from outside the body Built-in emergency lamp automatically activates if main lamp fails Automatic exposure for still or Polaroid photography includes override capability for fine control Malfunction indicator provides instant information on malfunctions in the emergency system Olympus EVIS CV-140 Video Processor Features: Compatible with the full range of endoscopes from EVIS 100, 130 and 140 series endoscopes Wide screen image functionality with used in conjunction with Q series endoscopes such as GIF-Q140 and CF-Q140L Pre-set scope switch functions. Endoscopist has a choice from up to 20 pre-set endoscope switch functions Pre-program patient data.Get Latest Price from the seller We are a Sole Proprietorship firm and we source products from the reliable market vendors which can be availed from us at reasonable prices. We are also involved in offering best-in-class Surgical Equipments Repairing Services and Modular OR Projects And Services to our esteemed clients. Apart from this, we also export our products to US, Australia, Canada, China, South America, etc. Under the guidance of “Mr. Mehul Patel” (Owner), who holds profound knowledge and experience in this domain, we have been able to aptly satisfy our clients. Profound knowledge derives from appreciating the significance of individual pieces of knowledge or experience and fitting them together into a coherent network. It is clearly reflected in its corporate claim: “Sharing Expertise”. Sharing knowledge across all company divisions creates a broader, sounder knowledge base for everyone involved, resulting in far sighted, detailed solutions and maximum safety for the benefit of the patient and in the interests of the user.Get Best Deal I agree to the terms and privacy policy All rights reserved. Products and names mentioned are the property of their respective owners.

    Transillumination Feature Increases illumination to allow confirmation of target area from outside the body. Automatically returns to original setting after approximately 7 seconds. We are here to help. You may be visiting our site outside of business hours or over the weekend. Please send us a message below with your questions and we will make sure to respond as soon as possible. Please hold on. Have you got a question. Write to us! We look forward to working with you. Up to 40 files of patient data can be pre-entered into memory to expedite procedure turn around Manual override offers variable adjustment by the endoscopist. Automatic Exposure Control for Still Photography Automatically sets light source at the optimum exposure for still or Polaroid photography. Manual override gives the endoscopist complete control of this function. Built-In Emergency Lamp The CLV-U40 system includes a built-in 150W Halogen emergency lamp which is automatically actuated in the event of Xenon lamp failure. Malfunction Indicator Any malfunction in the emergency system triggers the panel light malfunction indicator. Transillumination Feature Increases illumination to allow confirmation of target area from outside the body. Automatically returns to original setting after approximately 7 seconds. Incididunt sint officia non cow, ut et. Cillum porchetta tongue occaecat laborum bacon aliquip fatback flank dolore short loin ball tip bresaola deserunt dolor. Shoulder fugiat ut in ut tail swine dolore, capicola ullamco beef occaecat meatball. Laboris turkey in et chuck deserunt ad incididunt do.

    When combined with the CV-160 video system center, the CLV-160 provides a system that is a full 80mm narrower and 35% smaller than previous Olympus models, allowing for the entire system to be installed on a dedicated cart together with a video monitor and other ancillary equipment. Via Stripe the best way to accept payments online and in mobile apps. We handle billions of dollars every year for forward-thinking businesses around the world. All rights reserved. Design by It Design Group. We are a non-profit group that run this service to share documents. We need your help to maintenance and improve this website. Please update your browser. We suggest using Google Chrome or Mozilla Firefox.La fuente de luz de xenon de 300 W proporciona aproximadamente una mayor intensidad de luz para imagenes mas claras y vividas para mejorar la observacion detallada. Solo en combinacion con los alcances de la serie 200. El ajuste de densidad de luz optimo para la grabacion de video selecciona automaticamente la sensibilidad ideal requerida. El control Manual ofrece un ajuste variable por el endoscopio. El Control de exposicion automatico para la fotografia fija automaticamente la fuente de luz en la exposicion optima para la fotografia fija o Polaroid. El control Manual proporciona al endoscopio un control completo de esta funcion. Lampara de Emergencia integrada el sistema CLV-U40 incluye una lampara halogena de emergencia incorporada de 150 W que se acciona automaticamente en caso de fallo de la lampara de xenon. Indicador de mal funcionamiento cualquier mal funcionamiento en el sistema de emergencia activa el indicador de mal funcionamiento de la luz del panel. La funcion de transiluminacion aumenta la iluminacion para permitir la confirmacion del area objetivo desde fuera del cuerpo. Vuelve automaticamente a la configuracion original despues de aproximadamente 7 segundos.

    This page is part of GeneralManual.Com Network Olympus CLV-U40 Evis Universal Light Source User Manual. RSS. By operating the mode selector, the light source can be adjusted for any range. From the EVIS 100, 130, 140 and 200 Series videoscopes to OES fibroscopes and all rigid endoscopes. The manual override offers variable adjustment by the endoscopist. Manual override gives the endoscopist complete control of this function. It can automatically adjust its light density for video recording or still image capture, resulting to optimal image quality. It also ensures seamless operations with its emergency halogen lamp, allowing surgeons to complete their procedures even if the examination lamp fails. When combined with the 200 series scopes, it provides approximately 50 percent increased light intensity for clearer and sharper images enabling detailed observation during endoscopic treatments and interventions. It can also instantly adjust its light density for video recording while it automatically configure to optimum exposure on capturing still images. The user can still manually override these settings. If the examination lamp fails, it is equipped with a halogen emergency lamp which allows surgeons to complete the procedure. The emergency lamp can last up to 500 hours of continuous usage, making it a reliable back-up until the examination lamp is replaced. A smart Malfunction indicator lights up when there is any issue in the emergency system. Try selecting a filter (e.g. a category) or entering a keyword, then click elsewhere on the page: the store will show you how many search results your search will return, before you actually run the search. Please upgrade your browser or activate Google Chrome Frame to improve your experience. This new design and power assures clear, accurate observation even of distant points.

    Connect the endoscope connector of the fiberscope to the light source referring to the instruction manual for the light source. 3. Push the video plug of the scope cable EXERA II into the video connector socket of the instrument all the way until it clicks, holding this instrument with a hand so that it will not move. Confirm that the “UP” mark points upwards (see Figure 4.3). 4. Connect the scope side connector of the scope cable EXERA II to the endoscope, referring to the instruction manual of the endoscope. Fiberscope and camera head 1. Ensure that this instrument and all connected devices are turned OFF. 2. Connect the endoscope connector of the fiberscope to the light source, referring to the instruction manual for the light source. 3. Push the video plug of the camera head into the video connector socket of the instrument all the way until it clicks, holding this instrument with a hand so that it will not move. Confirm that the “UP” mark points upwards (see Figure 4.3). 4. Connect the video adapter and camera head to the eyepiece section of the fiberscope, referring to the instruction manuals for the video adapter and camera head. Rigidscope and camera head 1. Ensure that this instrument and all connected devices are turned OFF. 2. Connect the light guide cable to the light source, referring to the instruction manual for the light source. 3. Push the video plug of the camera head into the video connector socket of the instrument all the way until it clicks, holding this instrument with a hand so that it will not move. Confirm that the “UP” mark points upwards (see Figure 4.3). 4. Attach the light guide cable, video adapter and camera head to the rigidscope, referring to the instruction manuals for the light guide cable, video adapter and camera head. Summary of connection Figure 4.4 4.3 Turning the video system center ON 1. Turn the ancillary equipment ON. 2. Turn the instrument ON by pressing the power switch (see Figure 4.5).

    The indicator above the power switch lights up. Figure 4.5 3. The endoscopic image appears on the monitor (see Figure 4.6). Figure 4.6 4.4 Recall of user preset data 1. Press the “Shift” and “F2” keys together. The “User preset” menu appears on the monitor (see Figure 4.7). Figure 4.7 Figure 4.8 2. Click the desired user name in the user name dialog box. The selected user name is highlighted. 3. Check if the correct user name is selected, then click “Select”. The result of the adjustment will be displayed on the monitor for a few seconds (see Table 4.4). Table 4.4 6. If the adjustment failed, perform the operation of steps 4. and 5. again. 7. Switch to the normal mode by operating the mode button of the light source. The sub image appears on the monitor (see Figure 5.3). Figure 5.3 4. Press the “PinP” button to change the display. The transitions of the displays are different according to the settings in “Us. Figure 5.4 Figure 5.5 Image enhancement mode (ENH.) 1. Press the “ENH.” button to change the enhancement mode (see Figure 5.6). The indicator above the button lights up and the selected mode is displayed on the monitor for a few seconds. Figure 5.6 2. To switch OFF the image enhancement at any mode, press and hold the “ENH.” button. The indicator above the button goes OFF. Figure 5.7 Iris mode 1. Press the “IRIS” button on the front panel to switch between auto mode and peak mode alternately. The brightness level is displayed on the “EXPOSURE” indicator. STOP button and PC card indicator 1. Press the “STOP” button before removing the PC card. The PC card status indicator goes OFF. Figure 5.11 Table 5.3 PC card slot and eject button Figure 5.12 Table 5.4 1. Insert the xD picture card into the PC card adapter. 2. Push the PC card adapter all the way into the PC card slot. Figure 5.13 3. The video system center recognizes the PC card, and the PC card status indicator lights up green. 1. Press the “STOP” button. The PC card status indicator goes OFF (see Figure 5.

    El CV-140 permite al usuario mejorar, congelar y ajustar la configuracion de color para proporcionar imagenes claras y precisas desde el interior del cuerpo. Estamos registrados por la FDA y respaldamos nuestros productos ofreciendo una garantia de devolucion de dinero del 100% sin condiciones si no estas completamente satisfecho. Zgrum Medical se especializa en cirugia Bariatrica, general, endoscopia flexible y rigida, ortopedica, traumatismos, columna vertebral y herramientas electricas, implantes y una variedad de otros equipos medicos y desechables. Llevamos todas las marcas de nombres principales de bariatric, cirugia general y urologia desechables, incluyendo suturas, grapas, tijeras armonicas y endocomo EndoGIA, eticon Echelon, alcances de Olympus, Pentax y Fujinon, camaras y fuentes de luz de Stryker, Storz y Linvatec. Tambien ofrecemos una linea completa de traumatismos ortopedicos, columna vertebral y herramientas electricas, incluyendo juegos modulares de manos sinthes, conjuntos de fragmentos pequenos y grandes, conjuntos de columna vertebral Stryker y Medtronic, ?Salon de 3 M Medtronic y mas. Zgrum Medical esta dedicado a ofrecer el equipo de marca mas alto al precio mas bajo. Nuestra presencia internacional nos permite proporcionar a nuestros clientes equipos medicos nuevos, usados y reacondicionados de marcas de confianza en 10-60% por debajo de los precios de los fabricantes. Nuestro volumen y compra proactiva nos permite ofrecer los precios mas bajos posibles a nuestros medicos, centros de cirugia, hospitales y vendedores de todo el mundo. Hemos estado sirviendo a la comunidad medica internacional de hospitales, centros de cirugia, medicos privados y dispensarios veterinarios en todo el mundo y somos expertos en envios a todo el mundo. ?We talk about espa to; OC. Llama a nuestro personal experto hoy al (520) 495-0391 o (888) ZGRUM88.

    Mas informacion sobre nosotros en esta historia de Alibaba destacada Hemos estado sirviendo a la comunidad medica internacional de hospitales, centros de cirugia, medicos privados y dispensarios veterinarios en todo el mundo y somos expertos en envios a todo el mundo. ?We talk about Espa to; OC.Si encuentras algun problema con respecto a los resultados de la traduccion, tus sugerencias son bienvenidas. Toda la informacion del producto y del proveedor en el idioma o idiomas distintos del ingles que se muestra en esta pagina es informacion de www.alibaba.com traducida por la herramienta de traduccion de idiomas automaticamente. PinP composite terminal 14. PC card slot 15. Eject button 16. PC card status indicator 17. STOP button 18. Iris mode (IRIS) button 19. Iris mode indicators 20. Image enhancement mode (ENH.) button 21. Image enhancement mode indicators 22. VCR remote terminal 12. Fuse box 13. AC power inlet 14. Light control terminal 15. Light source terminal 16. Digital OUT terminal 19. PC OUT2 terminal 20. Monitor remote terminal 21. Composite OUT terminal 22. Monitor OUT terminal 23. Potential equalization terminal 2.3 Keyboard 1. F1 key 2. F2 key 3. F3 key 4. F4 key 5. F5 key 6. F6 key 7. F7 key 8. F8 key 9. F9 key 10. F10 key 11. F11 key 12. F12 key 13. Print screen key 14. Endoscopic image 12. Confirm that the brightness of the image on the monitor remains constant. Confirm that the light emitted from the distal end of the endoscope changes in your palm. 4. Hold the distal end of the endoscope 3 cm from your palm. Use a piece of gauze, etc.View the image on the monitor. 5. Confirm that the brightness of the image on the monitor changes when the light source's brightness level is changed. 3.4 Inspection of the monitor display 1. Turn the instrument ON. Confirm that the “UP” mark points upwards (see Figure 4.3). Figure 4.3 EVIS series videoscope and ultrasonic videoscope 1. Ensure that this instrument and all connected devices are turned OFF. 2.

    14). Figure 5.14 2. Press the eject button. 3. Press the eject button again. The PC card adapter comes out slightly (see Figure 5.15). Figure 5.15 4. Pull the PC card adapter straight out. RESET button Table 5.5 1. Press and hold the “RESET” button on the front panel (see Figure 5.16). All front panel indicators should blink for about 1 second, then the settings are reset. Figure 5.16 5.2 Keyboard Domepoint 1. Press the domepoint using your finger tip. The arrow pointer on the screen moves to the direction corresponding to the pressed part of the domepoint. Figure 5.17 2. Move the arrow pointer to a text box area. Click the text box to place the cursor. Figure 5.18 3. Click a button on the menu to move the highlight, or perform the function of the button. Every time the two keys are pressed, the contrast mode changes. Image enhancement (“F9”) 1. Press the “F9” key to display the current enhancement mode for a few seconds. 2. During displaying the mode on the monitor, press the “F9” key to change the enhancement mode (ex. The indicator above the key lights up to show the tone selected. Figure 5.47 2. Press the arrow keys to adjust the level of the selected tone. 3. Press the “COLOR” key to select the next tone and adjust it the same way. Freeze (“FREEZE”) 1. Press the “FREEZE” key (see Figure 5.48) to freeze the endoscopic image. 2. Press the “FREEZE” key again and the frozen image returns to the live image. Figure 5.48 Release (“RELEASE”) Figure 5.49 1. Press the “RELEASE” key to record the endoscopic image on the recording devices assigned. The PC card status indicator lights up green (see Figure 5.56). Figure 5.56 2. Press the “FREEZE” key to pause the endoscopic image (see Figure 5.57). 3. Check the frozen image if it is suitable to record. If not, press the “FREEZE” key again to return to the live image and repeat steps 2. and 3. Figure 5.57 4. Press the “RELEASE” key (see Figure 5.57) to record the image. It may take around several seconds to record the images.

    5. During recording, the PC card status indicator blinks orange, and the endoscopic image returns to the live image. PC card menu Figure 5.58 Basic operation of the PC card menu 1. Insert the PC card into the PC card slot. The PC card status indicator lights up green (see Figure 5.59). Figure 5.59 2. Press the “Shift” and “F4” keys together (see Figure 5.60). The message “Please wait” is displayed on the monitor, then the folder list screen appears (see Figure 5.61). Figure 5.60 Figure 5.61 Table 5.10 3. Click an image folder in the folder list. The patient data is displayed on the right side of the window. 4. Click “Load” or press the “Enter” key. The message “Please wait” is displayed on the monitor, then the thumbnail screen appears (see Figure 5.62). The thumbnail-sized images for the annotation image is not an image but an icon. Figure 5.62 5. Perform file operation such as playback and deletion of images, etc. 6. Click “Back” or press the “Esc” key to return to the previous screen. Or press the “Shift” and “F4” keys together to return to the endoscopic image. Formatting of the PC card 1. Display the folder list screen (refer to “Basic operation of the PC card menu” on page 111). 2. Click “Format” (see Figure 5.63). A confirmation message is displayed to ask if the card can be formatted. Figure 5.63 3. Click “No” to go back to the folder list screen instead of formatting. Click “Yes” to start formatting. During formatting, the message “Please wait” appears on the screen and the PC card status indicator of the video system center blinks orange. 4. The PC card status indicator lights up green after formatting has been completed and the message “Complete” appears on screen. A notification of normal or abnormal completion appears on the monitor. Playback images from the PC card 1. Display the thumbnail screen (refer to “Basic operation of the PC card menu” on page 111). 2. Click a thumbnail image to playback. The selected image should be edged with a thick frame.

    The shooting date and time of the image are displayed on the right side of the window. Figure 5.64 3. Click “View” or press the “Enter” key. The message “Please wait” is displayed on the monitor, then the normal screen image selected appears (see Figure 5.65). Figure 5.65 4. Click “ ” to playback the images before and after the image currently being played back. 5. Click “Zoom”. The message “Please wait” is displayed on the monitor, then the full screen image appears (see Figure 5.66). Figure 5.66 6. Press the “Esc” key to return to the normal sized playback screen. Or press the “Shift” and “F4” keys together to return to the endoscopic image screen. Deleting images from a PC card 1. Display the thumbnail screen (refer to “Basic operation of the PC card menu” on page 111). 2. Click a thumbnail image to be deleted. The selected thumbnail is edged with a thick frame. The shooting date and time of the image are displayed on the right side of the window. Figure 5.67 3. Click “Delete”. A confirmation message appears on the monitor. 4. Click “No” to go back to the thumbnail screen instead of deleting. Click “Yes” to delete the selected image. 5. Click “Back” or press the “Esc” key to return to the folder list screen. Deleting folder from PC card 1. Display the folder list screen (refer to “Basic operation of the PC card menu” on page 111). 2. Click the image folder to be deleted. The patient data is displayed on the right side of the window (see Figure 5.68). Figure 5.68 3. Click “Delete”. A confirmation message appears on the monitor. 4. Click “No” to go back to the folder list screen instead of deleting. Click “Yes” to delete the selected folder. 5. Click “Back”, press the “Esc” key, or press the “Shift” and “F4” keys together to return to the endoscopic image. Annotation of images 1. Display the thumbnail screen (refer to “Basic operation of the PC card menu” on page 111). 2. Click “Annotate” (see Figure 5.69). Figure 5.69 3.

    The annotation selection screen appears (see Figure 5.70). Figure 5.70 4. Click “ ” to scroll the thumbnail images if necessary. 5. Click the required thumbnail image. The selected image is edged with a thick frame. The shooting date and time of the image are displayed on the right side of the window (see Figure 5.70). 6. Click one of the position buttons on the screen. The number of the selected image appears at the position button and the selected image is edged with a thick frame in the color of the position button (see Figure 5.71). Figure 5.71 7. Select up to 4 images repeating steps 4. to 6., and then proceed with “Annotating” on page 121. Playback image annotation 1. Display the thumbnail screen (refer to “Basic operation of the PC card menu” on page 111). 2. Click an annotation icon to be played back. The selected icon is edged with a thick frame (see Figure 5.73). Figure 5.73 3. Click “View” or press the “Enter” key. The annotation screen appears on the monitor (see Figure 5.74). Figure 5.74 4. Click “Print” to print out the images on the video printer. A confirmation message appears on the monitor. 5. Click “No” to go back to the annotation screen instead of printing. Click “Yes” to print the images with the patient data and the comment. 6. Click “Back” or press the “Esc” key to return to the thumbnail screen. Playback the images using the personal computer 1. Insert the PC card into the PC card slot of the personal computer. If not, press the “FREEZE” key again to return to the live image and repeat steps 1. and 2. Figure 5.76 3. Press the “RELEASE” key (see Figure 5.76) to record the image. The indicator above the “PRINT QTY.” key indicates the number. 2. Press the “FREEZE” key to freeze the endoscopic live image. 3. Check the frozen image if it is suitable for recording. If not, press the “FREEZE” key again to return to the live image and repeat steps 2. and 3. 4.

    Press the “CAPTURE” key or “RELEASE” key to capture the endoscopic image into the memory of the video printer. The CVP counter on the monitor increments by one (see Figure 5.81). Figure 5.81 5. When the number of images captured reaches the number of images to print on a print sheet, printing starts automatically. The indicator above the “PRINT” key lights up during printing. 6. To start printing before the number of images captured reaches the number of images to be printed on a print sheet, press the “PRINT” key anytime. The indicator above the “PRINT” key lights up during printing. 1. Press the “DEL IMAGE” key a number of times until the CVP counter shows the image number to be overwritten. Figure 5.82 2. Press the “CAPTURE” key or “RELEASE” key to overwrite the new image on the previous image. The “Patient Data” menu appears on the monitor (see Figure 5.84). Figure 5.83 Figure 5.84 2. Click the buttons with the arrow pointer to operate the menu. Table 5.17 3. Click “Back” to return to the endoscopic image. The next patient data input screen appears. 7. After finishing entering the data, click “Back” to return to the patient name list (see Figure 5.88). Figure 5.88 8. Click again “Back” to return to the endoscopic image. Displaying patient data 1. Press the “Shift” and “F3” keys together to display the “Patient Data” menu (see Figure 5.89). Figure 5.89 2. Click the desired patient name in the patient name list. 3. Click “Select”. The selected patient data is displayed on the endoscopic image. Editing previously entered patient data 1. Press the “Shift” and “F3” keys together to display the “Patient Data” menu (see Figure 5.90). Figure 5.90 2. Click the desired patient name in the patient name list. The selected patient name is highlighted. 3. Click “Edit”. The patient data input screen appears (see Figure 5.91). Figure 5.91 4. Click the data to be modified and place the cursor in the data area. 5. Enter the data in the text boxes. 6.